Additional Information  
 
Host Interface 4 Gb Fibre Channel, SAS, or Gb iSCSI
RAID Controller 64-bit RISC-based
ProcessorDedicated XOR engine
Active-Active or Active-Passive Failover/Failback (See Model Specs)
Firmware in Flash ROM for easy upgrade
System voltage and temperature self-monitoring
Largest RAID set addressable by GUI: 64 TB
Concurrent I/O commands
Tagged Command queuing up to 256
Auto-negotiate FC-AL, point-to-point, or switched fabric (FC only)
RAID Operation RAID levels 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID and JBOD
Multiple RAID Sets
Configurable dedicated or global hot spare operation
Drive hot swapping
Drive roaming
Automatic background rebuild
Online RAID expansion
Intelligent drive handling
Variable stripe size per controller (optimization for random or sequential I/Os)
Max # of Logical Drives 16 if configured with less than 1GB Cache ; 32 if configured with 1GB or more
Max # of Partitions per LD 16 if configured with less than 1GB Cache ; 64 if configured with 1GB or more
Max # of LUNs 128 if configured with less than 1GB Cache ; 1024 if configured with 1GB or more
RAID Levels RAID levels 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID and JBOD
Drive Capacity SATA: 250, 500, 750 GB, & 1 TB (7200 RPM)
SAS: 73, 147, 300 GB (15K RPM), & 400 GB (10K RPM)
Drive Interface SAS 3 Gb/s & SATA 3 Gb/s
Visual/Audible Status Indicators Power and drive failure indication on drive trays
Built-in audible alarm & mute
Front Panel LCD and LED indicators. LED status indicators on rear for controller, cache, battery, network link, power supplies, & fans.
Management Software

RAIDWatch Java-based GUI manager software via in-band or network.
SANWatch Java-based GUI manager software via in-band or network with Snapshot option.
Firmware-embedded manager via RS-232C.
NPC (Notification Processing Center) module for event notification over Email, fax, cell phone (SMS), LAN broadcast, SNMP traps, & Instant Message (MSN).

SANWatch Specifications:

Specifications Express Professional
Capacity Maximum number of source volumes 4 Subsystem Logical Drive limitations
Maximum Snapshots per source volume 8 128
Maximum number of snapshots per system 32 Up to 1024, depending on cache size and Logical Drive capacity
Online Snapshot Image Mapping 4 128
Snapshot Scheduler and Automated Pruning N/A Yes
RAID Controllers 1 2
Space Threshold Setting and Automated Purging N/A Yes
Ready-only Access Yes Yes
OS Flush Agent support Yes Windows Server 2003

HeritageRAID-2S RAID Fibre Chanel Host Model Specifications

Part Number H2S12100F24 H2S12200F24 H2S16100F24 H2S16200F24
Description 12 Bay
Single Controller
12 Bay
Dual Controller
16 Bay
Single Controller
16 Bay
Dual Controller
Form Factor 2U Rack 2U Rack 3U Rack 3U Rack
Host Interface 4 Gb FC 4 Gb FC 4 Gb FC 4 Gb FC
RAID Controllers 1 2 1 2
Standard Memory 512 MB
(Up to 2 GB)
512 MB per controller
(Up to 2 GB per controller)
512 MB
(Up to 2 GB)
512 MB per controller
(Up to 2 GB per controller)
Cache Battery Option Yes Option Yes
Active/Active Failover No Yes No Yes
Host Channels 2 4 2 4
Host Ports 2 4 2 8 w/ Embedded Hub
Max # of Drives 12 (60 w/ 4 JBODs) 12 (48 w/ 4 JBODs) 16 (80 w/ 4 JBODs) 16 (48 w/ 2 JBODs)
Disk Interface SAS
SATA 3.0
SAS
SATA 3.0
SAS
SATA 3.0
SAS
SATA 3.0
SAS Expansion Ports N/A N/A 1 2
JBOD Expansion N/A N/A 4 - 16 Bay JBODs 2 - 16 Bay JBODs
Ext. Connections

2 - SFP Host
1 - SFF-8088 Exp.
1 - RJ-45 10/100
2 - RS-232

2 - SFP Host
1 - SFF-8088 Exp.
1 - RJ-45 10/100
2 - RS-232
2 - SFP Host
1 - SFF-8470 Exp.
1 - RJ-45 10/100
2 - RS-232
8 - SFP Host
2 - SFF-8470 Exp.
1 - RJ-45 10/100
2 - RS-232
Power Supplies 2 - 350W Redundant, Hot Swap 2 - 530W Redundant, Hot Swap 2 - 530W Redundant, Hot Swap 2 - 530W
Redundant, Hot Swap
Cooling Fans 3 2 2 2
Height (mm/in.) 88/3.46 (2U) 88/3.46 (2U) 131/5.16 (3U) 131/5.16 (3U)
Width (mm/in.) 482/18.98 482/18.98 482/18.98 482/18.98
Depth (mm/in.) 505/19.88 516/20.31 504.3/19.85 504.3/19.85
Voltage Input 90-260V AC 90-260V AC 90-260V AC 90-260V AC
Power Consumption 350W 530W 530W 530W
Frequency 63/47 Hz 63/47 Hz 63/47 Hz 63/47 Hz
Operating Temperature 0 to 35 °C 0 to 35 °C 0 to 35 °C 0 to 35 °C
Relative Humidity 5-90%, non-condensing 5-90%, non-condensing 5-90%, non-condensing 5-90%, non-condensing
Altitude Sea level to 12,000 ft Sea level to 12,000 ft Sea level to 12,000 ft Sea level to 12,000 ft
Certifications cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR

HeritageRAID-2S RAID SAS Host Model Specifications

Part Number H2S12100S H2S12200S H2S16100S H2S16200S
Description 12 Bay
Single Controller
12 Bay
Dual Controller
16 Bay
Single Controller
16 Bay
Dual Controller
Form Factor 2U Rack 2U Rack 3U Rack 3U Rack
Host Interface SAS SAS SAS SAS
RAID Controllers 1 2 1 2
Standard Memory 512 MB
(Up to 2 GB)
512 MB per controller
(Up to 2 GB per controller)
512 MB
(Up to 2 GB)
512 MB per controller
(Up to 2 GB per controller)
Cache Battery Option Yes Option Yes
Active/Active Failover No Yes No Yes
Host Ports 2 - SFF-8088 4 - SFF-8088 2 - SFF-8470 4 - SFF-8470
Max # of Drives 12 (60 w/ 4 JBODs) 12 (48 w/ 3 JBODs) 16 (80 w/ 4 JBODs) 16 (64 w/ 3 JBODs)
Disk Interface SAS
SATA 3.0
SAS
SATA 3.0
SAS
SATA 3.0
SAS
SATA 3.0
SAS Expansion Ports 1 - SFF-8088 2 - SFF-8088 1 - SFF-8470 2 - SFF-8470
JBOD Expansion 4 - 12 Bay JBODs 3 - 12 Bay JBODs 4 - 16 Bay JBODs 3 - 16 Bay JBODs
Ext. Connections

2 - SFF-8088 Host
1 - SFF-8088 Exp.
1 - RJ-45 10/100
2 - RS-232

4 - SFF-8088 Host
2 - SFF-8088 Exp.
1 - RJ-45 10/100
2 - RS-232

2 - SFF-8470 Host
1 - SFF-8470 Exp.
1 - RJ-45 10/100
2 - RS-232

4 - SFF-8470 Host
2 - SFF-8470 Exp.
1 - RJ-45 10/100
2 - RS-232
Power Supplies 2 - 350W Redundant, Hot Swap 2 - 530W Redundant, Hot Swap 2 - 530W Redundant, Hot Swap 2 - 530W
Redundant, Hot Swap
Cooling Modules 3 2 2 2
Height (mm/in.) 88/3.5 (2U) 88/3.5 (2U) 131/5.16 (3U) 131/5.16 (3U)
Width (mm/in.) 482/19 482/19 482/18.98 482/18.98
Depth (mm/in.) 516/20.3 516/20.3 504.3/19.85 504.3/19.85
Voltage Input 90-260V AC 90-260V AC 90-260V AC 90-260V AC
Power Consumption 350W 530W 530W 530W
Frequency 63/47 Hz 63/47 Hz 63/47 Hz 63/47 Hz
Operating Temperature 0 to 35 °C 0 to 35 °C 0 to 35 °C 0 to 35 °C
Relative Humidity 5-90%, non-condensing 5-90%, non-condensing 5-90%, non-condensing 5-90%, non-condensing
Altitude Sea level to 12,000 ft Sea level to 12,000 ft Sea level to 12,000 ft Sea level to 12,000 ft
Certifications cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR

HeritageRAID-2S RAID iSCSI Host Model Specifications

Part Number H2S16100I2 H2S16200I2
Description 16 Bay
Single Controller
16 Bay
Dual Controller
Form Factor 3U Rack 3U Rack
Host Interface GbE iSCSI GbE iSCSI
RAID Controllers 1 2
Standard Memory 512 MB
(Up to 2 GB)
512 MB per controller
(Up to 2 GB per controller)
Cache Battery Option Yes
Active/Active Failover No Yes
Host Ports 4 - RJ-45 8 - RJ-45
Max # of Drives 16 (80 w/ 4 JBODs) 16 (64 w/ 3 JBODs)
Disk Interface SAS
SATA 3.0
SAS
SATA 3.0
SAS Expansion Ports 1 - SFF-8088 2 - SFF-8088
JBOD Expansion 4 - 16 Bay JBODs 3 - 16 Bay JBODs
Ext. Connections

4 - RJ-45 Host
1 - SFF-8088 Exp.
1 - RJ-45 10/100
2 - RS-232

8 - RJ-45 Host
2 - SFF-8088 Exp.
1 - RJ-45 10/100
2 - RS-232
Power Supplies 2 - 530W
Redundant, Hot Swap
2 - 530W
Redundant, Hot Swap
Cooling Modules 2 2
Height (mm/in.) 131/5.16 (3U) 131/5.16 (3U)
Width (mm/in.) 482.6/19 482.6/19
Depth (mm/in.) 504.3/19.85 504.3/19.85
Voltage Input 90-260V AC 90-260V AC
Power Consumption 530W 530W
Frequency 63/47 Hz 63/47 Hz
Operating Temperature 0 to 35 °C 0 to 35 °C
Relative Humidity 5-90%, non-condensing 5-90%, non-condensing
Altitude Sea level to 12,000 ft Sea level to 12,000 ft
Certifications cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR

HeritageRAID-2S JBOD Model Specifications

Part Number H2S12000S1 H2S12000S2 H2S16000S1 H2S16000S2
Description 12 Bay
Single I/O Module
12 Bay
Dual I/O Module
16 Bay
Single I/O Module
16 Bay
Dual I/O Module
Form Factor 2U Rack 2U Rack 3U Rack 3U Rack
Host Interface SAS SAS SAS SAS
I/O Modules 1 2 1 2
Max # of Drives 12 12 16 16
Disk Interface SAS
SATA 3.0
SAS
SATA 3.0
SAS
SATA 3.0
SAS
SATA 3.0
SAS Expansion Ports 1 2 1 2
JBOD Expansion Yes Yes Yes Yes
Ext. Connections 2 - 4x SAS
SFF-8470
4 - 4x SAS
SFF-8088
2 - 4x SAS
SFF-8470
4 - 4x SAS
SFF-8470
Power Supplies 2 – 460W Redundant, Hot Swap 2 – 460W Redundant, Hot Swap 2 – 530W Redundant, Hot Swap 2 – 530W Redundant, Hot Swap
Cooling Fans 2 2 2 2
Height (mm/in.) 88/3.5 (2U) 88/3.5 (2U) 131/5.16 (3U) 131/5.16 (3U)
Width (mm/in.) 482/19 482/19 482/19 482/19
Depth (mm/in.) 522/20.55 522/20.55 504.3/19.9 504.3/19.9
Voltage Input 90-260V AC 90-260V AC 90-260V AC 90-260V AC
Power Consumption 460W 460W 530W 530W
Frequency 63/47 Hz 63/47 Hz 63/47 Hz 63/47 Hz
Operating Temperature 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C
Relative Humidity 5-90%, non-condensing 5-90%, non-condensing 5-90%, non-condensing 5-90%, non-condensing
Altitude Sea level to
12,000 ft
Sea level to
12,000 ft
Sea level to
12,000 ft
Sea level to
12,000 ft
Certifications cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR cUL, FCC A, CE & CISPR

Warranty & Support

HeritageRAID-SA ships with:
- 3 year warranty
- 1 year advance replacement warranty on defective components
- 9 x 5 toll-free technical support

Warranty uplifts are available for:
- 3 year advance replacement
- 24 x 7 tech support
- 8 x 5 x NBD onsite with 24 x 7 tech support

Note: Product specifications subject to change without notice.
RAIDWatch, SANWatch, and EonPath are trademarks of Infortrend Technology, Inc.